Surge Protectors
IMPORTANT REPORT



1. At the direct stroke of lightning, electric current is typically 30 kA (M.A. Umann recorded currents up to 200 kA). A single direct strike can damage or destroy Gas Tube Element and/or body of a protector, regardless of its current rating. The energy discharge is triggered when voltage increases to the rated voltage of the gas tube element. Consequently, almost the entire remaining energy shall be dissipated at once. The timing of discharge is normally some hundreds nanoseconds to microseconds to trigger level, and some hundred microseconds to milliseconds for remaining energy.

2. Effects of lightning by induced electromagnetic fields vary widely in energy. Induced damage ranges from similar effect as direct stroke for large energy, to no damage from small induction. The life of a Gas Tube Element is eventually consumed by small energy surge events.

3. Almost all types of large current types of Gas Tube Element are ceramic sealed and cannot be visually checked. The gas tube element is activating even on small energy surges. Each surge reduces the life. You never able to judge by your eye how much life your gas tube has left in case of Ceramic sealed type. The life is normally 400~600 times under test condition of 8 micro sec. / 20 micro sec. per industry standards. Ask your vendors to recommend how to check life of their surge protectors in field.

4. The lightning in the natural electro magnetic environment averages as much as several hundred surges per day including large and small that has reported officially. Manually monitoring it 24/7 is impossible. If a Gas Tube Element fails when you are not aware of it, you will be under Non-Protected situation even you have scheduled element changes.

5. RF TEC Mfg., Inc. uses specially made Gas Tube Elements with Glass Body for 5 kA current rating. This reduces Non-Protected situations. Looking inside Gas Tube through the Glass Body will let you see the actual condition of Gas Tube Element. The inside glass darkens with use; a black color indicates time for replacement. The glass eventually blackens in case of small induced surges, but goes entirely black at once from a direct strike as pictures on the our web site show. There is not available large electric current type with glass body gas tube element that can be visually checked. The result is almost the same with large electric current ceramic type, since the energy of direct and large inductive strikes exceed the rating of even the largest electric current type elements.


(From left to right: Original, Damaged 1, Damaged 2)

6. Some of our valuable customers kindly reported us what happened after stroke. Before using our In-Line Surge Protectors, their coaxial antenna cables were split and the radios were damaged. However, all those were saved when the next direct strike hit, after installation of our protectors. The gas tube element was destroyed, but the body is still good and the surge protector reused by simply replacing the gas tube element, easily installed in the field by the customer.

7. Stocking new surge protectors for replacement requires high investment, but replacing only gas tube elements is very economical.

8. There are tradeoffs for both large electric current type in Ceramic Sealed types and our Glass Tube types. We have confidence based on reports from the field that our Surge Protectors are generally the best solution for protecting your radio equipment and coaxial antenna cables.

9. Ceramic sealed gas tube elments are available in 10KA, 20KA, 30KA and 40KA current ratings. High rated types withstand high energy and are effective mostly for inductive lightnings and EMP. Although longer life, the life is still limited. The life is also 200~600 times under standard test condition of 8/20 micro sec. per IEEE. Actual energy of lightning vary case by case, affecting life time. You never know it. Problem is that once large energy like direct strike or equivalent inductive lightning had come, "the life is over." Since then, you will be exposed and unprotected. Your surge protector has changed to just connector adapter, and you have no protection. You need to know whether your gas tube element inside protector is still effective. We are using special semi-transparent Glass sealed type that is rated 5KA. However, we have tested Lightning Impulse Cycle Test/Destroy Test at 10KA/500KV at Public Government Test Lab and passed 80 times. Higher than 10KA damage Connector in case of N-type even your N-type Plug and Cable Assemblies due to the structure of the connector. May be withstand one time for a lightning strike. We have confirmed damage even N-type Surge Protectors and Cable Assemblies of famous competitors during test. Higher than 10KA is NO Meaning.

Our design lets you see if your protector is still a protector or is dead. The body of the gas tube element changes body color occasionally into black by level of the energy. Center or entire gas tube completely in black color is time for replace. You can change gas tube inside by yourself. You need to know this matter. It is up to your decision that

ALWAYS STAY PROTECTED !

RF TEC Mfg., Inc.